7 MW Siemens Steam Turbine

SIEMENS T6210/ENG25/25 STEAM TURBINE

Type: ENG 25/25  

Design Power: 7637  kW

Maksimum Output Power: 7680  kW

Turbine Design Speed: 12065  rpm

Over Speed Trip  (mechanic/electric): 13271 rpm

Min.Speed (Turning gear speed): 199 rpm

Live Steam Flow: 75 tph

Live Steam Pressure: 61 bar(a)

Live Steam Temperature: 425 C

Extraction Steam Pressure (Nominal): 2.8 bar(a)

Extraction Steam Pressure (Max.): 13.8 bar(a)

Extraction Steam Pressure (Min.): 11.8 bar(a)

Steam Back Pressure (Nominal): 6.2 bar(a)

Steam Back Pressure (Max.): 6.5 bar(a)

Steam Back Pressure (Min.): 5.9 bar(a)

GENERATOR            

AVK Deutschland GmbH & Co.KG

Type:        DIG 163 M/4  

Years:       2001        

Cos Ø :     0.8  

Power:     10000 KVA      

kVA Nr.    8324412  A101        

Voltage:  6300 V    

Frekans:  50 Hz.      

Cooling:   Air (Direct Cooling)

Cooling air max.inlet temp:   40 ° C       

Cooling air min.inlet temp:    10 ° C       

Cooling Air Flow:    5,3 m³/h 

For detail information about steam turbine contact us.